Homepage | Set Home | Add to Favorites
Member

Jinan Retek Industries Inc.


Products
  • No Category
Search
 

Friends links
  • No link

Wood Boiler- Heat Exchanger Coil
Click image to view full size image
Product: Views:302Wood Boiler- Heat Exchanger Coil 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-11-03 11:29
  Inquiry
Details

This new style 12*12 water to air heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install.
This unit is easier to install than others on the market because it attachs from the front instead of the side.

The 12*12 water to air heat exchanger
can also be used as a stand alone heat source by simply attaching
a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or
the cold air return of a furnace. Please note that if installed in the cold air return you will need to install
a 3 way zone valve in order for the fan to operate properly.
Model:

Item
Btu CFM Pressure Drop Air Pressure Drop Water GPM
12x12 50,000 700 0.5 0.2 6
12x18 80,000 800 0.5 0.2 6
14x14 85,000 800 0.5 0.2 7
14x18 95,000 800 0.5 0.2 7
15x15 98,000 1000 0.51 0.206 8
16x16 90,000 1250 0.51 0.257 8
16x18 100,000 1650 0.81 0.254 10
18x18 130,000 2000 0.91 0.325 12
18x20 140,000 2350 1.32 0.359 14
19x20 150,000 2500 1.49 0.388 15
20x20 160,000 2700 1.38 0.4 16
22x22 170,000 2400 2.08 0.287 21
22x25 180,000 2800 2.10 0.355 21
24x24 200,000 3300 2.14 0.457 21

These compact units are designed to maximize heat transfer by utilizing a series of 3/8" copper tubes with a high density of aluminum fins.
These fins are spaced such that the fin density is 12 fins per inch.
This design enables heating loads of 50,000-60,000 Btu per square foot (please see performance chart).
Despite such high fin density there is minimal pressure drop through these coils.
This heat exchanger is crafted of stainless steel.
Because water flows through this exchanger at such a high rate of speed, it cleans itself.
The model of heat exchanger you will require is based on the volume of water that you need it to handle.
Applications thaools, hot tubs, and waste water. This particular heat exchanger features a capacity of 60,000 BTU/H.
heat exchangers such as this one can be used for include oil coolers, transmission and engine coolers, boiler sample coolers

Pls feel free to contact me if you are interested in our products!
Inquiry